Analisis Susut Non Teknis dengan Metode Pendekatan Presentase Pembebanan di PT. Delta Dunia Tekstil

Agus Isa Putra
Djuniadi Djuniadi

Abstract


As the Electricity is one of the most important needs for human life. PT PLN (Persero) as a company providing electricity needs has an obligation to provide electricity to the people of Indonesia. The loss of energy that occurs in the process of distributing electricity to customers is still one of the main problems that is still being faced by PLN. Therefore, it is necessary to make efforts to reduce the losses so that the reliability of the electric power system is getting better. Currently, an AMR (automatic meter reading) system has been implemented. for calculating distribution losses, customer load analysis, observing effectively the possibility of irregularities in the measurement of electrical energy at customers. This research aims to calculate the amount of non-technical losses and potential losses with the AMR system at PT Delta Dunia Textile. The non-technical shrinkage calculation method used in this study is the loading percentage approach for each phase. After carrying out the measurements, the results were obtained, namely the current in the R phase was not measured, as a result, PT PLN (Persero) UP3 Pekalongan experienced a loss of underbilled power. The reason for not measuring the current in the R phase is because the Current Transformer (CT) cable is almost broken, so you have to rewiring the CT cable again. By implementing this AMR system, it is easy to find out the customer's energy usage load profile data so that when an anomaly occurs in the measuring device it can be handled immediately.


Keywords


AMR;non-technical losses

Teks Lengkap:

PDF

Referensi


[1] Putri, I. E. N., Subari, A. Optimasi pelaksanaan penertiban pemakaian tenaga listrik (p2tl) sebagai upaya peningkatan saving kwh dan penekanan susut non teknis di pt. pln (persero) rayon semarang selatan. Gema Teknologi, 18(2).

[2] Syamsudin Z, Suyanto H, Elektro T, Tinggi S, Pln T. ANALISIS SUSUT ENERGI PADA TEGANGAN RENDAH DI WILAYAH PT. PLN (PERSERO) AREA BULUNGAN. Vol. 5, Jurnal Sutet.

[3] Pangestu AB, Defi R, Putri M, Hudallah N, Andrasto T. ANALISIS KEANDALAN SISTEM DISTRIBUSI JARINGAN SUTM DI PT. PLN (PERSERO) UP3 YOGYAKARTA. Jurnal SIMETRIS. 2023;14(1).

[4] Muhtar A, Antarissubhi IH, Elektro J. ANALISIS RUGI DAYA JARINGAN DISTRIBUSI PRIMER PT. PLN ULP SENGKANG SULAWESI SELATAN. Vol. 13, Vertex Elektro.

[5] Eka Putra Surusa F, Humena S, Yanto Nani F. Analisa Susut Non Teknis Menggunakan Automatic Meter Reading (AMR) Pada Pelanggan Potensial. 2022;4.

[6] Agustina E, Fitri Amalia A. PENURUNAN SUSUT NON TEKNIS PADA JARINGAN DISTRIBUSI MENGGUNAKAN SISTEM AUTOMATIC METER READING DI PT. PLN (PERSERO).

[7] PENGUKURAN DAN PERHITUNGAN Sugianto A, Untara P. STUDI SUSUT ENERGI PADA SISTEM DISTRIBUSI TENAGA LISTRIK MELALUI.

[8] Pahiyanti NG. Penurunan Susut Jaringan Dengan Penertiban Pemakaian Tenaga Listrik. SUTET. 3 Juni 2019;9(1):36–45.

[9] Putra WJ, Sukardi D. Pengoptimalan Pelaksanaan Penertiban Pemakaian Tenaga Listrik (P2TL) untuk Menekan Susud Non Teknis di PT PLN (Persero)Unit Layanan Pelanggan (ULP) Balai Selasa. 2022;3(1):311–8.

[10] Desmira, D., Aribowo, D., Anggraini, R. Analisis pelanggaran pemakaian tenaga listrik pada pelanggan tegangan menengah (20 kv) di pt. Pln (persero) distribusi banten area cikupa. Jurnal Pengembangan Riset dan Observasi Sistem Komputer, 5(2).

[11] Daniel H, Prodi D, Elektro T, Yogyakarta U, Ringroad J, 55285 UJSYDI. UPN “Veteran” Yogyakarta. 2013;

[12] Fauzie Ariyanti R. IDENTIFIKASI PENYEBAB SUSUT ENERGI LISTRIK PT PLN (PERSERO) AREA SEMARANG MENGGUNAKAN METODE FAILURE MODE & EFFECT ANALYSIS (FMEA).

[13] Ayu D, Intan K, Prasetyono RN. Analisis Pelanggaran Pemakaian Tenaga Listrik Pada Pelanggan di PT. PLN (PERSERO) ULP Bumiayu Di Masa Pandemi Covid-19. 2021.

[14] Tanjung AR, Zain A, Susanto H. Analisa Penurunan Susut Non Teknis Dengan AMR PLN (Studi Kasus PT. Tjokro Bersaudara Bontang Kaltim). Jurnal Sinergi Jurusan Teknik Mesin. 4 Desember 2019;17(1):1.

[15] Susanto B, Jumnahdi M, Sunanda W, Elektro JT, Teknik F, Bangka U, dkk. MENEKAN SUSUT ENERGI MELALUI ANALISIS KEWAJARAN KONSUMSI ENERGI LISTRIK PELANGGAN PADA PLN UP3 BANGKA.




DOI: https://doi.org/10.24176/simet.v15i1.10936

Article Metrics

Abstract views : 41| PDF views : 35

Refbacks



free hit counter View My Stats

Indexed by:

Dimensions logo

 

Flag Counter

Creative Commons License
Simetris : Jurnal Teknik Mesin, Elektro dan Ilmu Komputer is licensed under a Creative Commons Attribution 4.0 International License.

Dedicated to: